Range Medium Severity
F11 Appliance Error Code

Dacor Range F11 Error: Igniter module comm fault

This dacor range f11 error code guide explains what this fault means for your Dacor appliance and how to respond safely. What F11 Means on a Dacor Range F11 on a Dacor range signals that the main control board cannot communicate with the surface burner igniter module. All electronic surface ignition stops. The code appears […]

~25%

DIY Fixable

From $200

Typical Repair Cost

45-90 min

Pro Repair Time

Quick Assessment

Answer to continue safely

Is it safe to keep using?

No. Gas ignition communication failure means the system cannot verify safe ignition. Do not use gas modes.

Can I reset the code?

Yes. A breaker reset may restore communication. Persistent F11 indicates a module or wiring fault.

When to stop immediately?

Stop if you notice: Do not use surface burners without ignition unless you have a separate flame source and exercise extreme caution — unlit gas is dangerous., Stop if continuous clicking persists after a power cycle — do not leave the range powered unattended in this state..

Symptoms You May Notice

Surface burners will not spark when knobs are turned

Turning any surface burner knob to the ignite position produces no clicking sound and no spark — the igniter module is offline and not responding to ignition commands.

Continuous clicking without a knob being turned

In some failure modes, the igniter module produces continuous rapid clicking across all burners simultaneously without any user input, then goes silent and displays F11.

F11 appears on the oven display, not on a burner indicator

The fault code shows on the main oven control display — surface burners have no individual displays on Dacor ranges, so all igniter faults route to the central display.

Oven functions may continue normally

On dual-fuel Dacor ranges where the oven uses electric elements, the oven section continues to operate normally while only electronic surface ignition is affected.

Possible Causes

1

Failed surface burner igniter module

The electronic igniter spark module that distributes ignition voltage to all surface burners has failed internally. This is a single component that controls all burner igniters on Dacor Modernist and Contemporary ranges.

Requires Professional
2

Communication wiring fault between board and igniter module

The signal wiring between the main control board and the igniter module is open or shorted — moisture from boilovers is a frequent cause on range models where the igniter module sits near the cooktop surface.

DIY Possible
3

Moisture contamination in the igniter module

Liquid spilled on the cooktop has reached the igniter module housing, causing the module to short internally or creating a phantom fault signal that the board interprets as F11.

DIY Possible

Safe Checks You Can Do

These checks are safe for homeowners. No disassembly required. Do not remove panels or access internal components.
  1. 1

    Dry out the cooktop area

    If F11 appeared after a liquid spill, turn off the range at the breaker and allow the cooktop surface and the area beneath the burner grates to dry completely — at least 24 hours. Remove the grates and burner caps and wipe down all surfaces around the igniter electrode bases.

    A hair dryer on a low heat setting aimed at the burner bases for 5 minutes can speed drying — do not use high heat.

  2. 2

    Power cycle after drying

    After the 24-hour dry period or if no spill occurred, turn off the breaker for 5 minutes, then restore power. Attempt to ignite a surface burner. If clicking restores and F11 clears, moisture was the cause.

    If clicking resumes but one specific burner does not spark, the individual burner igniter wire is the issue, not the module.

When to Call a Professional

Contact a qualified technician if:

  • F11 persists after full drying and a power cycle — igniter module replacement required.
  • Individual burner igniter wires show burn marks or cracked insulation near the electrode base — harness repair needed.
  • Module replaced but F11 returns — control board communication output circuit has also failed.

Need Professional Help?

Find qualified technicians in your area for proper diagnostics and repair.

Range Repair Service Schedule Appointment